Wind Energy in Helsingborg

Annual yield

13,140

kWh/year

Payback period

not reached

CO₂ savings

0.2

t CO₂/year

Example calculation: 10 kW system, country average values

Frequently asked questions about Helsingborg

How much electricity does a 10 kW wind turbine produce in Helsingborg?

With a capacity factor of 15%, a 10 kW turbine in Helsingborg generates approximately 13140 kWh per year.

How much does a small wind turbine cost in Helsingborg?

A 10 kW wind turbine in Helsingborg typically costs around €40,000 including installation.

What is the payback period for a wind turbine in Helsingborg?

Given local wind conditions, the investment is not paid back within the 20-year horizon of this example calculation.

How much CO₂ does a wind turbine save in Helsingborg per year?

A 10 kW wind turbine in Helsingborg avoids approximately 0.2 tonnes of CO₂ per year.

Assumptions and provenance

This example calculation is disclosed in full. Every quantity below enters the figures above exactly as stated — a specialist can recompute them or substitute their own assumptions.

Payback (cumulative)
not reached in 20 years

Sum of the nominal annual net benefits, including degradation, price escalation and replacement costs — not discounted. This is the figure shown above.

Payback (discounted)
not reached in 20 years

The same cash flows, discounted at the nominal rate the net present value uses. Always the later of the two.

Payback (static)

Investment divided by the first year's benefit — without price escalation, degradation or replacement costs. Many quotes use this; depending on the assumptions it comes out shorter or longer.

Assumptions and provenance
QuantityValueSource / note
System size10 kWExample system of this page
Investment€40,000 (€4,000/kW)IEA Wind TCP Task 27 / WindEurope: 3.000–6.000 €/kW installiert für Kleinwind, Mittelwert bei 10 kW
Operating cost€1,200/a
Electricity price0.180 EUR/kWhEurostat nrg_pc_204, Band DC, 2025-S2
Feed-in tariff0.0600 EUR/kWh
Self-consumption share20 %Wind generates at night and in winter — the share is structurally below that of solar.
Degradation0.5 %/a
Price escalation2.0 %/a
Discount rate3.0 %/aNominal, matching the nominally escalating revenues
Horizon20 years
Grid CO₂ factor13 g/kWhEEA, greenhouse gas emission intensity of electricity generation (seed), 2023
Wind speed (data source)7.51 m/sAnnual mean at 50 m reference height
Wind speed (hub height)5.64 m/sLogarithmic wind profile, converted to 15 m
Hub height15 m
TerrainSuburbanz₀ = 0.4 m
Weibull shape parameter k2.00
Air density1.247 kg/m³
Capacity factor15.0 % netGross 22.8 %, less 16 % losses · capped at 15 %, the loss chain gave 19.1 % — a deliberately conservative screening assumption

Data source: not recorded with this cached figure. Wind comes from the New European Wind Atlas, or from NASA POWER outside its coverage; which of the two produced this number was not stored alongside it, and it is not assigned retrospectively.

Non-binding initial assessment for an example system, not professional advice. Small wind requires an on-site wind measurement before any investment decision.

Wind potential for Helsingborg

Check wind potential for Helsingborg