Vuosituotto

2 651

kWh/year

Takaisinmaksuaika

not reached

CO₂-säästöt

1.0

t CO₂/year

Example: 10 kW system, country average values

Usein kysytyt kysymykset Münchenstä

How much electricity does a 10 kW wind turbine produce in München?

With a capacity factor of 3%, a 10 kW turbine in München generates approximately 2651 kWh per year.

How much does a small wind turbine cost in München?

A 10 kW wind turbine in München typically costs around €40,000 including installation.

What is the payback period for a wind turbine in München?

Given local wind conditions, the investment is not paid back within the 20-year horizon of this example calculation.

How much CO₂ does a wind turbine save in München per year?

A 10 kW wind turbine in München avoids approximately 1.0 tonnes of CO₂ per year.

Assumptions and provenance

This example calculation is disclosed in full. Every quantity below enters the figures above exactly as stated — a specialist can recompute them or substitute their own assumptions.

Payback (cumulative)
not reached in 20 years

Sum of the nominal annual net benefits, including degradation, price escalation and replacement costs — not discounted. This is the figure shown above.

Payback (discounted)
not reached in 20 years

The same cash flows, discounted at the nominal rate the net present value uses. Always the later of the two.

Payback (static)

Investment divided by the first year's benefit — without price escalation, degradation or replacement costs. Many quotes use this; depending on the assumptions it comes out shorter or longer.

Assumptions and provenance
QuantityValueSource / note
System size10 kWExample system of this page
Investment40 000 € (4 000 €/kW)IEA Wind TCP Task 27 / WindEurope: 3.000–6.000 €/kW installiert für Kleinwind, Mittelwert bei 10 kW
Operating cost1 200 €/a
Electricity price0,370 EUR/kWhEurostat nrg_pc_204, Band DC, 2025-S2
Feed-in tariff0,0778 EUR/kWh
Self-consumption share20 %Wind generates at night and in winter — the share is structurally below that of solar.
Degradation0,5 %/a
Price escalation2,0 %/a
Discount rate3,0 %/aNominal, matching the nominally escalating revenues
Horizon20 years
Grid CO₂ factor363 g/kWhUmweltbundesamt, Strommix Deutschland (vorläufig 2024), 2024
Wind speed (data source)4,35 m/sAnnual mean at 50 m reference height
Wind speed (hub height)3,26 m/sLogarithmic wind profile, converted to 15 m
Hub height15 m
TerrainSuburbanz₀ = 0.4 m
Weibull shape parameter k2,00
Air density1,247 kg/m³
Capacity factor3,0 % netGross 3,6 %, less 16 % losses

Data source: New European Wind Atlas (NEWA) · version Mesoscale Atlas v1 · as of 2019 (release), model years 2005–2018 · licence: CC BY 4.0

Non-binding initial assessment for an example system, not professional advice. Small wind requires an on-site wind measurement before any investment decision.

Tuulipotentiaali Münchenlle

Check wind potential for München